DT-SENSE CARBON MONOXIDE SENSOR is a sensor module-based MQ-7, i.e. the sensors that react to the levels of carbon monoxide gas in the air. This module has output of digital data as well as hardware design minimalist aimed to facilitate the process of use of sensor MQ-7. This module can be applied as an early warning alarm, or gas detector to help industrial processes involving carbon monoxide gas.

DT-SENSE CARBON MONOXIDE SENSORS are designed using high quality SMD components to be used in applications that require reliable performance and space requirements are minimal. On the side of the interface, there are two options for the user that is TTL UART with baud rate 38400 bps or I2C module allowing forcascade up to 8 pieces.

Dimensions: 5.6 cm (L) x 4 cm (W) x 2.8 cm (H)

  • Product Detail
  • Download
  • Application Note

Specifications:

  • Working voltage: 5 VDC.
  • Target gases: carbon monoxide (CO).
  • Detection Range : 20-2000 ppm.
  • Interface:
    • UART TTL: 38400 bps, 8 data bits, 1 stop bit, no parityno flow control.
    • I2C: cancascade up to 8 modules in one line of communication.
  • Using 10-bit ADC for conversion of analog data from sensors.
  • Have an output in the form of digital data with a value of 0 to 1023 (ADC conversion results).
  • There is 1 piece variable resistors for setting the threshold value manually.
  • Provided a couple of jumpers to configure the pull-up I2C, load resistor, as well as variable resistors threshold.
  • Features of control on/off with 2 working mode selection i.e. hysterisis and window.
  • The i/o pins are compatible with the level of voltage TTL and CMOS.
  • Features 2 LED as an indicator.
  • Equipped with a series of EMI filters to reduce electromagnetic interference.
  • Gas sensors are compatible with:
    • MQ-3 (alcohol).
    • MQ-4 (methane).
    • MQ-6 (LPG).
    • MQ-7 (carbon monoxide).
    • MQ-135 (air quality).
    • MG-811 (carbon dioxide).

 

Includes:

  • 1x DT-SENSE CARBON MONOXIDE SENSORS.

Application Note Table

Article File Desc date
AN224n.pdf AN224.zip
[AN224] Antarmuka DT-Sense Gas Sensor menggunakan Arduinoâ„¢ UNO

Interfacing between DT-Sense Gas Sensor and Arduino™ UNO, with simple testing program using i2cmaster Library

16-04-2015